Design & Specification

  • Shell: The shell shall be fabricated from tested quality steel duly welded, comprising of the base frame, peripheral structure, self-draining roof, one entry door and 03 nos. of windows. The eight corners shall be sufficiently strengthened to facilitate transportation, lifting & placing.
  • Base Frame: The base frame shall be made of pressed mild steel channel section. The main structural element shall be of 125 mm x 75 mm "I" beam and cross members shall be of 'C' channels section size 100 mm x 50 mm.
  • Side and End Walls: The side and end frame shall be made out of pressed sections of suitable profiles / Pillars of sufficient strength. Exterior wall shall be made up of 1.6mm MS specially corrugated sheet, whereas 9mm particle board would be used for interior walls. These steel sheets shall be treated for corrosion resistant. Panels shall be vertically corrugated. Sheets shall be continuously welded to top side and base structure so as to offer better strength to weight ratio.
  • Flooring Systems: On the bottom frame 18 mm thick Marine plywood shall be fixed by means of self tapping screw. PVC Vinyl flooring shall be fixed on the plywood sheet.
  • Roof: Self draining type roof shall be made out of 1.6mm thick M.S. Sheet, adequate roof bows are to be provided. Roof shall be adequately cambered for draining of rainwater. Interior paneling shall be done in 9mm particle board with adequate insulation.
  • Paint: Red oxide primer for Bunk House & chlorinated Rubber for final 2 coats.
  • Insulation: 50 mm thick Glass wool Insulation shall be used for walls & 75 mm thick insulation material to be provided for roof.
  • Inner Paneling: The interior shall be aesthetically finished so as to give custom built appearance with extremely high quality workmanship. All vertically & horizontal corners shall be neatly & smoothly finished with Aluminum sections. The Paneling of side walls & roof shall be of 9 mm thick decorative laminated board.
  • Main Entry Door: The size of the door shall be of 6' height x 3' width. The door shall be of external opening type made out of the same material as wall panels with door closing unit. The construction of the door shall be double skin steel construction with 40 mm thick glass wool insulation. The peripheral edges of the door shall be sealed with double gaskets to make it waterproof & leak proof. The door interior shall be finished with same material matching with that of the bunk house interior. The door shall be provided with locking arrangement with separate handles on both sides of the door as required. Main door will be insulated & fitted with Godrej Mortise lock & power bolt.
  • Aluminum Windows: 03 number of Aluminum powder coated windows, sliding type shall be provided, made of Aluminum section, 5 mm thick, clear vision glasses are to be fitted to it.
  • Electrical System: The Bunk House will be provided with electrical wiring suitable for 250 volt, 50 HZ single phase AC power supply. All electrical wiring shall be concealed. Bulk head & 2 nos. of tube lights shall be provided. Suitable copper cables shall be used for lighting circuits. The copper cables used will be of 3/1.9 cable for lighting circuits. ISI mark & concealed in PVC conduits insulated copper wire shall be used for wiring to be done in PVC conduit with small size distribution board with MCB protection and to separate with main supply.

 


Contact via E-mail
Contact via SMS
Metal Arch Porta Cabins Private Limited
Suhel Ahmed (Business Development Manager)
Survey No. 98, Shil-Mahape Road , Mumbra,
Thane - 400601, Maharashtra, India
Call Us: 
Call Response Rate: 90%
Share Us :
F G T L



Home  |   About Us   |  Products  |  Site Map  |   Contact Us

© Metal Arch Porta Cabins Private Limited. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited

Metal Arch Porta Cabins Private Limited